VMware 3V0-23.25 Dumps

(261 Reviews)
Exam Code 3V0-23.25
Exam Name Advanced VMware Cloud Foundation 9.0 Storage
Update Date 27 Nov, 2026
Total Questions 77 Questions Answers With Explanation
$79

Prepare Smarter for the 3V0-23.25 with Pass4itexam

At Pass4itexam, we believe in smart preparation. That’s why we’ve built a complete guide to help you succeed in the VMware 3V0-23.25 exam. Whether you’re a first-time test taker or revisiting certification, our expert-curated PDF dumps for 3V0-23.25 are your shortcut to confidence and clarity.

This isn’t just a question bank—it’s a full prep system. Our materials reflect real exam objectives, with relevant scenarios and actual exam-style questions. You’ll get to know the format, practice effectively, and reduce test-day anxiety.

What to Expect from Our 3V0-23.25 Preparation

1. Straightforward Study Material
  • Exam-Aligned Content: Every topic we cover is mapped to VMware's objectives, so no wasted time.
  • Easy to Understand: No fluff, no filler—just simplified concepts that actually stick.
2. Real Practice for Real Exams
  • True-to-Exam Questions: Practice on material that mirrors the real 3V0-23.25 exam format.
  • Instant Feedback: Learn from your mistakes and understand the “why” behind the answers.
3. Smart Strategies That Work
  • Master time management to reduce pressure during the exam.
  • Use our proven techniques to handle tricky or unexpected questions.
  • Learn patterns and question logic to boost your confidence.
4. Always Updated, Always Relevant
  • 90 Days Free Updates: We keep your dumps current, so you’re never studying outdated content.
  • Based on Real Feedback: We monitor exam changes and adjust quickly.

Your Success Is Our Promise

If you use our 3V0-23.25 prep materials and still don’t pass, we’ll refund you—simple as that. No hidden terms. No stress.

We stand behind our products with a full 100% Money-Back Guarantee, because we know our materials deliver results.

Final Thoughts

If you’re serious about passing the VMware 3V0-23.25 certification, you’re in the right place. Our resources are designed to help you save time, study smarter, and get certified faster.

Start now with Pass4itexam’s 3V0-23.25 PDF dumps — and take control of your certification journey.

0 Review for VMware 3V0-23.25 Exam Dumps
Add Your Review About VMware 3V0-23.25 Exam Dumps
Your Rating
Question # 1

A customer attaches an external Fibre Channel (FC) VMFS datastore to a VMware Cloud Foundation (VCF) workload domain for backup staging. The administrator must confirm that the datastore is visible to all hosts, and that path and device health alarms will trigger should a fabric link or path fail. Which action should the administrator take to verify this?

A. Run esxcli vsan storage list on each host to view VMFS datastore path status.  
B. In vCenter verify the external VMFS datastore connectivity, paths and multipath health.  
C. Execute storage.monitor.getStatus via VCF SDK to receive a consolidated health summary of all VMFS, vSAN and NFS datastores.  
D. Use esxcli fc adapter list followed by vmkfstools --inspectpaths to validate health for the VMFS LUN.

Question # 2

An administrator is tasked with deploying a VMware Cloud Foundation (VCF) WorkloadDomain that meets the following requirements:• vSAN ESA as principal storage• RAID-6 with FTT=2• Support for Storage Traffic SeparationThe administrator is provided the following hardware to perform the task:• Four ESX hosts, each host contains:24 CPU cores96 GB memoryTwo 25GbE network NICs12 NVMe devices 4 TB each, connected to a single SATA/SAS/NVMe Tri-modecontrollerWhat four changes must the administrator make to the hardware beforedeploying the new Workload Domain? (Choose four.)

A. Increase the ESX host count to a minimum of seven.  
B. Increase the ESX host count to a minimum of six.  
C. Increase the CPU quantity on each host to a minimum 32.  
D. Increase the Tri-mode controller quantity on each host to two, with six NVMe devices connected to each.
E. Increase the network NICs on each host to minimum of four 25 GbE network NICs.  
F. Replace the network NICs on each host to a minimum of two 100 GbE network NICs.  
G. Increase the memory on each host to a minimum 128 GB.  
H. Replace the Tri-mode controller on each host with a dedicated NVMe controller.  

Question # 3

An administrator has been tasked with suggesting storage models for a new VMware CloudFoundation (VCF) Private Cloud. The following information has been provided:• All existing implementations of VMware vSphere use the existing third-party block-basedstorage solution.• The block-based storage solution only has sufficient scale, capacity and IOPS to cater forthe new workload storage requirements.• There is a dedicated and highly resilient storage area network connecting hosts to theprovided block-based storage.• There are 5 existing hosts with enough CPU and RAM resources and resilient Host BusAdapters (HBAs) to cater for the new workload resource requirements only.• There is sufficient budget to purchase some hardware, however the solution must re-usethe existing hardware where possible.The administrator suggests the following high-level solution:• Single VCF Instance with a single Workload Domain.• Deploy 4 new servers to create a Management Domain.• Repurpose the 5 existing servers to create a single cluster in the Workload Domain.Which two storage models should the administrator recommend? (Choose two.)

A. iSCSI should be the supplemental storage solution for the VCF Workload Domain.  
B. iSCSI should be the principal storage solution for the VCF Management Domain.  
C. Fibre Channel should be the principal storage solution for the VCF Workload Domain.  
C. Fibre Channel should be the principal storage solution for the VCF Workload Domain.  
E. VMware vSAN should be the principal storage solution for the VCF Workload Domain.  

Question # 4

An administrator has been tasked with adding supplemental storage to an existing VMware Cloud Foundation (VCF) Workload Domain. The supplemental storage will add capacity for backup data and ISO images without impacting the principal storage used for live production workloads. What should the administrator recommend meeting the requirement?

A. Migrate Management Domain storage to a new cluster.  
B. Increase the VMFS principal storage allocation.  
C. Attach additional NFS volumes or iSCSI datastores.  
D. Replace all existing datastores with NVMe devices.  

Question # 5

An administrator is tasked with configuring the vSAN File Service to deliver NFS file shares for an Edge environment.Which three are required to deliver the service? (Choose three.)  

A. Create a dedicated port group for vSAN File Services in the DVS.  
B. If using an NSX-based network, ensure that MAC Learning is enabled.  
C. MAC Learning and Forged Transmits are disabled.  
D. Jumbo frames are enabled on the network and the DVS port group.  
E. Hosts connected to a DVS version 6.6.0 or later.  
F. vSAN Witness functionality is enabled on each VMkernel.  

Question # 6

An administrator is presented with the following scenario:• 20 TB of additional storage is being requested by a VM application owner.• The application has high CPU/Memory requirements that can only be satisfied by thecurrent cluster the application runs in.• The application has high IOPS and bandwidth requirements to run properly.• The existing vSAN cluster only has 10 TB of unused capacity.• The hosts in the cluster have no additional NVMe slots left.• The administrator does not have permission to purchase additional hosts or re-assignhosts from other vSAN clusters.• Other vSAN clusters exist in the environment that can satisfy the requirement.Which vSAN feature should be used to fulfill this scenario?

A. vSAN HCI Mesh  
B. vSAN Data Protection  
C. vSAN File Services  
D. vSAN Stretched Clusters  

Question # 7

An administrator is presented with the following scenario:• 20 TB of additional storage is being requested by a VM application owner.• The application has high CPU/Memory requirements that can only be satisfied by thecurrent cluster the application runs in.• The application has high IOPS and bandwidth requirements to run properly.• The existing vSAN cluster only has 10 TB of unused capacity.• The hosts in the cluster have no additional NVMe slots left.• The administrator does not have permission to purchase additional hosts or re-assignhosts from other vSAN clusters.• Other vSAN clusters exist in the environment that can satisfy the requirement.Which vSAN feature should be used to fulfill this scenario?

A. vSAN HCI Mesh  
B. vSAN Data Protection  
C. vSAN File Services  
D. vSAN Stretched Clusters  

Question # 8

While creating a recovery plan that matches the business continuity plan, an administrator needs to add custom steps to the recovery plan. Which three custom steps are available? (Choose three.)

A. IP reconfiguration  
B. Create writable Storage Snapshots  
C. Top level commands  
D. Pause
E. Message prompt  
E. Message prompt  

Question # 9

An administrator is managing a stretched vSAN ESA cluster where each site has threehosts.The following parameters apply to the storage policy being configured at the datastorelevel:• The policy is configured at the datastore level• Site disaster tolerance = Site mirroring - stretched cluster• Failures to tolerate = 1 failure - RAID-1 (mirroring)• Number of disk stripes = 1When inspecting some of the Virtual Machines (VMs), why do objects have 3 disk stripes?

A. ESA in RAID-1 always uses 3 stripes.  
B. Site mirroring has been configured.  
C. Each Virtual Machine has 3 objects.  
D. There is a policy configured at the Virtual Machine level.  

Question # 10

An administrator is planning the deployment of a new VMware Cloud Foundation (VCF)Workload Domain. The storage design decisions for the solution are:• NFS• NVMe over RDMA• No local storage is available to the hostsWhat is the storage solution build order for the Workload Domain?

A. vSAN OSA as principal storage, then add NFS and NVMe over RDMA as supplemental storage. 
B. vSAN ESA as principal storage, then add NFS and NVMe over RDMA as supplemental storage. 
C. NVMe over RDMA as principal storage, then add NFS as supplemental storage.  
D. NFS as principal storage, then add NVMe over RDMA as supplemental storage.  

Question # 11

An administrator notices alerts triggering IOPS and Disk Throughput storage performance problems in the Fibre Channel datastore in a VMware Cloud Foundation (VCF) Workload Domain. What can the administrator review to identify which Virtual Machines (VMs) may be experiencing storage IOPS and disk throughput performance issues?

A. vSAN Health dashboard.  
B. vSphere Storage Inventory dashboard.  
C. Live! vSphere Heavy Hitter VM dashboard.  
D. Storage Operations page.  

Question # 12

An administrator is troubleshooting a vSAN performance issue. In the vSAN cluster performance charts there is a high latency on the vSAN cluster. What is a possible cause of the performance issue?

A. The Virtual Machines are using PVSCSI controllers.  
B. Jumbo frames are enabled on the VMkernel adapters.  
C. Erasure Coding is disabled in the storage policy.  
D. There is congestion in one or more disk groups.  

Question # 13

A VMware Cloud Foundation (VCF) environment runs mixed workloads (OnlineTransaction Processing (OLTP) + analytics), with the following vSAN configuration:• 8 hosts (all-flash), ESA enabled.• Each host: 2 x 3.2 TB NVMe devices.• Compression is Enabled.• Checksum is Enabled.• Storage Policy: FTT=1 (RAID-5/6), Failures to Tolerate = 1 and Object Space Reservation= 0%.During peak OLTP load, vSAN resync I/O and backend congestion increase latencydespite having sufficient network bandwidth.What is the direct action the administrator can perform to improve write performance whilemaintaining data protection compliance?

A. Increase object reservation to 100% to pre-allocate capacity and prevent log-structuring overhead. 
A. Increase object reservation to 100% to pre-allocate capacity and prevent log-structuring overhead. 
C. Increase FTT to 2 with RAID-5/6 and disable compression.  
C. Increase FTT to 2 with RAID-5/6 and disable compression.  

Question # 14

A storage architect is designing a VMware Cloud Foundation (VCF) Workload Domain withthe following requirements:• vSAN File Services hosting multiple file shares.• Each department requires distinct protection levels and placement rules.Which option satisfies the requirements?

A. Create multiple IP Pools and bind each to a file server to be able to assign different storage policies.
B. Separate file shares by creating individual File Service clusters per department.  
C. Make sure the file share server VMS are tied to a vSphere Compute Policy during creation. 
D. Assign different vSAN Storage Policies to each file share during creation.  

Question # 15

An enterprise is planning to deploy a new vSAN ESA enabled cluster to their existingVMware Cloud Foundation (VCF) Private Cloud Workload Domain. The followingrequirements have been given:• 2 x 4 TB NVMe disks per host• FTT=1/RAID-5 for all deployed Virtual Machines• Expected dedupe/compression ratio = 1.5 (50%)• Reserve enough capacity to rebuild a host completely in case of a failure (Host RebuildReservation)• Operational Reserve of 10%• Expected overhead for filesystem, object, etc. of 25%How many hosts are required to meet a minimum usable capacity of 12 TB?

A. 6 hosts  
B. 3 hosts  
C. 4 hosts  
D. 5 hosts  

Question # 16

A vSAN ESA solution is configured using the following requirements:• Seven ESX Hosts, each host contains:32 CPU256 GB memory25 GbE network12 storage devices 4 TB eachOne storage pool using the 12 storage devices• RAID-6 with FTT=2If a storage

A. 50%  
B. 25%  
C. 8.3%  
D. 0%  

Question # 17

An administrator is working on a VMware Cloud Foundation (VCF) Workload Domain that was configured to use vSAN for principal storage. The administrator wishes to create and configure a datastore cluster to host tenant VMs using that vSAN backed storage across multiple clusters, mixed OSA and ESA, in the domain. What should the administrator consider?

A. When using vSAN datastores, Datastore Clusters are not supported. Each VM must be placed manually on the vSAN datastore.
B. When using vSAN as the underlying datastore, an administrator must create the datastore cluster via vCenter APIs, include the vSAN datastore(s) in it, enable Storage DRS, and ensure the VM Storage Policies reference the appropriate vSAN-capable datastore.
C. A datastore cluster can combine different storage types, such as vSAN, FC, and NFS datastores, as long as they are in the same vCenter; Storage DRS will treat them uniformly. 
D. vSAN OSA and ESA based datastores must be added to a datastore cluster tag and then selected as part of a single storage policy. 

Question # 18

vSAN encounters a noncompliant Virtual Machine and is able to locate a full replica of 55% of the votes for the noncompliant objects. What action will vSAN do with the Virtual Machine?

A. Automatically recover the noncompliant objects and mark the Virtual Machine as compliant. 
B. Power off the Virtual Machine.  
C. Mark the Virtual Machine as inaccessible as vSAN is not able to locate more than 60% of the votes for the objects.
D. Mark the Virtual Machine as orphaned.  

Question # 19

An administrator wants to protect a site from disaster and re-protect after fail-over. Industry regulations require to change the primary site every six months. Which two options are required during the inventory mapping and while running the recovery plans to fulfill this requirement? (Choose two.) 

A. Once fail-over is successful, reconfigure vSAN data protection to reverse replication.  
B. Use “Prepare reverse mappings” during inventory mapping creation.  
C. Use a test recovery plan.  
D. Once the fail-over is successful, re-protect from VMware Live Site Recovery.  
E. Extend the network between both sites.  

Question # 20

As part of standard operating procedures, when an administrator leaves the organization, a shallow rekey operation must be performed on a vSAN ESA cluster with vSAN Data-atRest Encryption enabled. Which key is rotated during a shallow rekey operation? 

A. Disk Encryption Key  
B. Host Key  
C. Key Derivation Key  
D. Key Encryption Key